Cedar Saunas

How to Build a Sauna, Part 4: Size, Place and Wire the Heater

The heater is the heart of the sauna, and the wrong size is the second most common mistake we see after missing vents. Too small and it runs flat out and never gets the room hot. Too big for the room and it overheats the space and shuts itself off. This is Part 4 of our 5-part sauna building guide: how to size the heater, where to put it and how to power it safely.

The short version

  • Heaters are rated for a room size in cubic feet. Measure the inside length x width x height.
  • Add about 4 cu ft for every square foot of glass, tile, stone or bare concrete. A full-glass door adds about 48 cu ft.
  • Solid log walls with no insulation: multiply the room volume by 1.5.
  • Pick a heater whose rated range puts your number near the middle, not at the edges.
  • Most electric heaters need a dedicated 240 V circuit. A 6 kW heater draws about 25 amps and an 8 kW about 33.
  • Follow the manual’s clearances to walls, ceiling and benches, and put a guard rail around the heater.

Step 1: Work out your sizing volume

  1. Measure the inside of the finished room in feet: length x width x ceiling height. A 6 x 8 ft room with a 7 ft ceiling is 336 cu ft.
  2. Add for glass and bare surfaces. Glass, tile, stone and concrete don’t hold heat like an insulated wall, so the heater works harder. Add about 4 cu ft for each square foot. A full-glass 24 x 73 in door is about 12 sq ft, so it adds about 48 cu ft.
  3. Adjust for log walls. If the walls are solid logs with no insulation, multiply the room volume by 1.5.

That gives you the sizing volume. Our 6 x 8 ft example with a glass door comes to about 384 cu ft. These are the same rules our heater sizing calculator uses.

Step 2: Match it to a heater’s rated range

Every heater lists a minimum and maximum room size. Pick one where your sizing volume falls near the middle of that range.

  • Below the minimum is a problem. A heater that’s too big for the room overheats it and trips its safety limit.
  • Right at the maximum means the heater runs hard all the time and takes a long time to heat up.
  • Outdoor saunas in cold climates and rooms with a lot of glass should lean toward the bigger size.
Room (7 ft ceiling)Room volumeWith a glass doorTypical electric heaterWood stove example
4 x 6 ft168 cu ft216 cu ft4.5 kW (solid door) or 6 kW (glass door)Small stoves for about 200+ cu ft
6 x 6 ft252 cu ft300 cu ft6 kWHarvia M3 (212 to 459 cu ft)
6 x 8 ft336 cu ft384 cu ft8 kWHarvia M3 or Narvi Kuru
8 x 8 ft448 cu ft496 cu ft9 kWNarvi Kuru (283 to 706 cu ft)

As a real example, the Harvia KIP electric heater comes in 4.5 kW (100 to 210 cu ft), 6 kW (170 to 300 cu ft) and 8 kW (250 to 425 cu ft). Our 384 cu ft example lands near the middle of the 8 kW range.

Sauna build planner

Enter the inside dimensions of the hot room. The numbers update as you type.

The long wall, where the benches go
7 ft is the sweet spot
A full-glass 24x73 door is about 12 sq ft
Room volume-
Heater sizing volume-Pick a heater whose rated range puts this near the middle
Typical electric heater size-
Electric draw at 240 V-Breaker and wire size come from the heater manual. Use a licensed electrician.
Fresh air, 6 changes an hour-Use this if you add an exhaust fan
Bench seats, one long row-About 2 ft of bench per person sitting up
Wall and ceiling paneling-Includes 12% for cuts, minus the door
Foil vapor barrier-
Insulation-Walls plus ceiling, before the door opening
Estimates for planning. Always check the heater's rated room size and installation manual. Want exact board counts? Our sauna packages count every board for you, and the heater sizing calculator matches heaters to your room. Questions? Call or text 218-760-2041.
Harvia KIP electric sauna heater with a stainless guard rail inside a cedar barrel sauna
A Harvia KIP electric heater in one of our barrel saunas. The guard rail keeps elbows and knees off the hot casing.

Step 3: Place the heater

  • Follow the manual’s clearances, every time. Each heater lists minimum distances to the side walls, the front, the ceiling and the benches. Measure from the finished paneling, not the studs.
  • Near the fresh air intake. The intake goes low under or beside the heater, so incoming air warms right away. See Part 3.
  • Below the top bench. The top of the stones should sit lower than the top bench so the heat and steam rise to the people sitting there.
  • Easy to reach for water. Leave room to ladle water onto the stones without leaning over the heater.
  • A guard rail. Put a wood rail or the maker’s safety railing around the heater so no one leans on it.
  • Solid mounting. Wall-mounted heaters need the blocking you added in Part 2.

Step 4: Power an electric heater safely

Full-size sauna heaters run on 240 V and need their own circuit. Here’s roughly what they draw:

HeaterCurrent at 240 V
4.5 kWabout 19 A
6 kW25 A
8 kWabout 33 A
9 kWabout 38 A
10.5 kWabout 44 A

The breaker and wire size come from the heater’s installation manual and your local electrical code, which usually call for more capacity than the raw draw. Plan for that when you look at your panel, and have a licensed electrician do the install. Most areas require a permit for this work.

  • Controls: some heaters have the controls built in. Others use a separate control panel mounted outside the hot room, often with Wi-Fi.
  • Temperature sensor: mount it exactly where the manual shows, usually on the wall or ceiling above the heater. Keep the fresh air intake from blowing on it.
  • Nothing standard inside: no regular outlets, switches or light fixtures in the hot room.
Sauna control box and power connection mounted on the outside wall of a cedar barrel sauna
The control box on the outside wall of one of our barrel saunas. Keeping controls and connections outside the hot room protects them from the heat.

Wood-burning stoves

Wood stoves are sized by rated room volume the same way. What’s different is the fire:

  • Chimney: use the maker’s chimney kit and its clearances through the ceiling or wall, with the right height above the roof.
  • Floor: set the stove on a non-combustible base like stone, tile or a stove floor plate.
  • Walls: add heat shields or a safety wall set where the manual calls for reduced clearances.
  • Exterior feed: a stove you load from outside keeps ash and firewood out of the hot room.
  • Carbon monoxide: put a CO alarm in the changing room or nearest room, not in the hot room.
Harvia M3 wood-burning sauna stove next to a firewood holder in a cedar sauna
A Harvia M3 wood stove, rated for 212 to 459 cu ft, on a protected floor with clearance to the bench.

Stones and the first heat

  • Fill the stone basket the way the manual shows. Stack loosely so air moves between the stones. Don’t pile stones on the elements.
  • Replace crumbled stones every year or two, depending on how much you use the sauna. Read how to use sauna rocks.
  • Burn in the heater before your first real session: run it hot for about an hour with the door cracked and the vents open. A little smell the first time is normal.

Heaters builders order from us most

From our shop: the call we get most often after a build goes like this: “the sauna takes forever to heat and never gets past 150.” Nine times out of ten, it’s a heater sized for the room on paper, with a big glass door or a concrete wall nobody counted. Send us your room size, door, glass and wall type before you buy, and we’ll tell you exactly which heater fits. Text Mike at 218-760-2041.

Next in the seriesPart 5: Paneling, benches, door, lights and floor
Read part 5

Sauna heater sizing questions

What size sauna heater do I need?

Multiply the inside length, width and height in feet to get cubic feet. Add about 4 cu ft for each square foot of glass or bare masonry, and multiply by 1.5 for uninsulated log walls. Then pick a heater whose rated range puts that number near the middle.

What size heater for a 6×8 sauna?

A 6 x 8 ft sauna with a 7 ft ceiling is 336 cu ft. With a full-glass door it sizes like about 384 cu ft, which is a good fit for an 8 kW electric heater or a wood stove rated for that range.

How many amps does a sauna heater need?

At 240 V, a 6 kW heater draws about 25 A and an 8 kW heater about 33 A. The breaker and wire size come from the heater manual and local code, and a licensed electrician should install the circuit.

Can a sauna heater be too big?

Yes. If the room is smaller than the heater minimum rated size, it overheats the room and trips its safety limit. Match the heater rated range to your room.

Building a sauna? Talk to a real person.

Cedar Sense is a family sauna business in Waubun, Minnesota. We help builders and homeowners size heaters, plan vents and order every part of a build in one shipment. Call or text 218-760-2041. Building saunas for clients? See our contractor pricing.

author-avatar

About Michael Vail

Mike Vail runs Cedar Sense, a family sauna business in Waubun, Minnesota, since 2019. He has delivered saunas to customers in more than 40 states and answers buyer questions himself at 218-760-2041.